一解決水利失調方法
首先,加(jia)節流(liu)孔(kong)板。空(kong)調(diao)(diao)(diao)靠近冷源環路、熱(re)力(li)(li)入口(kou)等部分(fen)管段,增加(jia)節流(liu)孔(kong)板,解決(jue)水(shui)力(li)(li)失調(diao)(diao)(diao)的(de)水(shui)系統(tong)熱(re)力(li)(li)末端流(liu)量、阻(zu)力(li)(li)計算準確(que),無法出現變(bian)(bian)化(hua)。所(suo)以,末端流(liu)量變(bian)(bian)化(hua)仍會導致水(shui)力(li)(li)失調(diao)(diao)(diao)、能源浪費。
其(qi)次,手(shou)(shou)動調(diao)(diao)節閥(fa)(fa)的(de)安裝(zhuang)。針對大型空調(diao)(diao)系統,選(xuan)擇手(shou)(shou)動調(diao)(diao)節閥(fa)(fa)難以(yi)進(jin)(jin)行調(diao)(diao)節,若對前端閥(fa)(fa)門(men)進(jin)(jin)行手(shou)(shou)動調(diao)(diao)節,會影響后端流量(liang)。調(diao)(diao)整(zheng)后端流量(liang),其(qi)前端流量(liang)會出現變化。所以(yi),調(diao)(diao)整(zheng)費(fei)力(li)、費(fei)時。針對復雜系統,工程師需具(ju)有調(diao)(diao)節閥(fa)(fa)門(men),若出現系統壓力(li)、負荷,對水力(li)系統進(jin)(jin)行重新(xin)調(diao)(diao)整(zheng)。
第三,動(dong)態(tai)(tai)流(liu)量平衡閥(fa)(fa)的(de)(de)安(an)裝。確(que)(que)定空調(diao)設備末端、熱力(li)入(ru)口的(de)(de)設計(ji)流(liu)量,按照(zhao)閥(fa)(fa)門(men)(men)處壓(ya)力(li)、流(liu)量變(bian)(bian)化的(de)(de)范圍,確(que)(que)定動(dong)態(tai)(tai)平衡閥(fa)(fa),將閥(fa)(fa)門(men)(men)安(an)置好,只需(xu)閥(fa)(fa)門(men)(men)處壓(ya)差(cha)變(bian)(bian)化,控(kong)制(zhi)閥(fa)(fa)門(men)(men)壓(ya)力(li),不需(xu)要人為調(diao)節。
二動態平衡閥特點
首(shou)先,動態平(ping)衡閥(fa)工作原理。對平(ping)衡閥(fa)閥(fa)芯過(guo)(guo)流(liu)(liu)面積(ji)進行調整,以(yi)(yi)適應閥(fa)門前后變(bian)(bian)化,實現流(liu)(liu)量(liang)(liang)控(kong)(kong)制。動態平(ping)衡閥(fa)屬于一個以(yi)(yi)改變(bian)(bian)局部(bu)阻力為(wei)主(zhu)的節流(liu)(liu)元件,針對不可(ke)(ke)壓(ya)縮流(liu)(liu)體,流(liu)(liu)量(liang)(liang)方程(cheng):Q=KA(△P),其中Q代表(biao)平(ping)衡閥(fa)流(liu)(liu)量(liang)(liang),K代表(biao)流(liu)(liu)量(liang)(liang)系數,A代表(biao)閥(fa)芯過(guo)(guo)流(liu)(liu)面積(ji),△P代表(biao)閥(fa)門的進出口(kou)壓(ya)差。當閥(fa)門開度(du)不變(bian)(bian)時,可(ke)(ke)忽視(shi)K值(zhi)變(bian)(bian)化。所以(yi)(yi),閥(fa)門流(liu)(liu)量(liang)(liang)維持A(△P)不變(bian)(bian)。平(ping)衡閥(fa)則由支撐裝置(zhi)、高精度(du)彈簧、過(guo)(guo)流(liu)(liu)閥(fa)膽構成(cheng),彈簧的受(shou)壓(ya)差對閥(fa)膽的過(guo)(guo)流(liu)(liu)大小(xiao)進行控(kong)(kong)制,進而恒定閥(fa)門流(liu)(liu)量(liang)(liang)。
其(qi)次,閥(fa)門工(gong)作(zuo)過程(cheng)。若(ruo)zui小啟動壓(ya)(ya)差(cha)(cha)大(da)于平(ping)衡(heng)閥(fa)的前后壓(ya)(ya)差(cha)(cha),則表示彈簧(huang)沒有(you)被壓(ya)(ya)縮,此(ci)時的流(liu)(liu)通(tong)面(mian)積(ji)zui大(da)。若(ruo)平(ping)衡(heng)閥(fa)門前后的壓(ya)(ya)差(cha)(cha)處于工(gong)作(zuo)范(fan)圍(wei)內,則彈簧(huang)被閥(fa)膽(dan)(dan)壓(ya)(ya)縮,處于工(gong)作(zuo)狀態,閥(fa)膽(dan)(dan)兩邊圓孔(kong)、幾何型通(tong)道(dao)經過水(shui)流(liu)(liu)。因閥(fa)膽(dan)(dan)處于運動狀態,幾何流(liu)(liu)型通(tong)道(dao)也由于變化,閥(fa)體(ti)流(liu)(liu)通(tong)面(mian)積(ji)也隨之變化。處于該壓(ya)(ya)縮范(fan)圍(wei)內,可基本恒(heng)定(ding)水(shui)流(liu)(liu)流(liu)(liu)量(liang)。若(ruo)平(ping)衡(heng)閥(fa)的前后壓(ya)(ya)差(cha)(cha)大(da)于工(gong)作(zuo)范(fan)圍(wei),彈簧(huang)被閥(fa)膽(dan)(dan)全(quan)部壓(ya)(ya)縮,只(zhi)有(you)閥(fa)膽(dan)(dan)兩邊圓孔(kong)有(you)水(shui)流(liu)(liu),即閥(fa)膽(dan)(dan)作(zuo)為固定(ding)調節器(qi),壓(ya)(ya)差(cha)(cha)和流(liu)(liu)量(liang)呈正比,壓(ya)(ya)差(cha)(cha)增大(da),流(liu)(liu)量(liang)也隨之增大(da)。
動態平(ping)衡(heng)閥通過一定(ding)壓力范圍,對(dui)空(kong)(kong)調(diao)末(mo)端(duan)(duan)流量(liang)zui大值(zhi)進(jin)行(xing)控制,可(ke)實現流量(liang)的自(zi)動恒定(ding),空(kong)(kong)調(diao)采暖的負荷不穩(wen)定(ding),系統(tong)調(diao)試被(bei)簡(jian)化,減少調(diao)試時(shi)間(jian)。尤其平(ping)衡(heng)閥在異程水系統(tong)的應用,可(ke)實現設計(ji)環境(jing)溫(wen)度、水力工(gong)況(kuang)平(ping)衡(heng),其他末(mo)端(duan)(duan)啟(qi)停對(dui)空(kong)(kong)調(diao)系統(tong)末(mo)端(duan)(duan)設備的運行(xing)不造成影響。
三實際工程中動態平衡閥的運用
首先,區域供(gong)暖。運用于(yu)熱力入(ru)口,確(que)(que)保(bao)系(xi)統(tong)流(liu)量(liang)(liang),室內溫暖閥、采(cai)暖系(xi)統(tong)需(xu)確(que)(que)保(bao)每(mei)個散熱器具有(you)足夠的流(liu)量(liang)(liang),動(dong)態平衡閥需(xu)確(que)(que)保(bao)恒定各立管流(liu)量(liang)(liang),使水平失調得到解決(jue)。
其次,空(kong)(kong)調(diao)系(xi)統。在大型空(kong)(kong)調(diao)系(xi)統、集中(zhong)式空(kong)(kong)調(diao)系(xi)統中(zhong),平(ping)(ping)衡(heng)閥設置(zhi)在空(kong)(kong)調(diao)設備(bei)的(de)末端,經過三(san)通(tong)電動閥確保設備(bei)的(de)運行(xing)流量(liang),平(ping)(ping)衡(heng)閥調(diao)整水力(li)工況(kuang),當(dang)水泵、冷卻(que)塔、冷熱源的(de)設計(ji)管線(xian)受到(dao)限制(zhi)時(shi),采用平(ping)(ping)衡(heng)閥防止負荷偏載,確保設備(bei)正常、安全運行(xing)。
四空調系統設計反感因該注意的問題
首先(xian),動(dong)(dong)(dong)(dong)態平(ping)(ping)(ping)衡(heng)(heng)(heng)閥無(wu)法調(diao)(diao)(diao)(diao)整負荷(he)(he)(he)。在(zai)空(kong)調(diao)(diao)(diao)(diao)系統設(she)計中,只能(neng)(neng)調(diao)(diao)(diao)(diao)節水(shui)力(li)平(ping)(ping)(ping)衡(heng)(heng)(heng),無(wu)法調(diao)(diao)(diao)(diao)節負荷(he)(he)(he),因誤(wu)解了動(dong)(dong)(dong)(dong)態平(ping)(ping)(ping)衡(heng)(heng)(heng)閥,極易認為平(ping)(ping)(ping)衡(heng)(heng)(heng)閥可(ke)(ke)(ke)調(diao)(diao)(diao)(diao)整采暖負荷(he)(he)(he)、平(ping)(ping)(ping)衡(heng)(heng)(heng)空(kong)調(diao)(diao)(diao)(diao),利用(yong)平(ping)(ping)(ping)衡(heng)(heng)(heng)閥代替電(dian)(dian)動(dong)(dong)(dong)(dong)兩(liang)通(tong)閥、三通(tong)閥。然而隨著室內負荷(he)(he)(he)、結構負荷(he)(he)(he)的動(dong)(dong)(dong)(dong)態變(bian)化(hua),空(kong)調(diao)(diao)(diao)(diao)設(she)備(bei)水(shui)量(liang)(liang)也實(shi)現動(dong)(dong)(dong)(dong)態變(bian)化(hua),即(ji)可(ke)(ke)(ke)確保室內溫(wen)度,也可(ke)(ke)(ke)達到節省的目的。大型空(kong)調(diao)(diao)(diao)(diao)系統的運用(yong),將(jiang)平(ping)(ping)(ping)衡(heng)(heng)(heng)閥設(she)置在(zai)空(kong)調(diao)(diao)(diao)(diao)設(she)備(bei)中,各設(she)備(bei)啟停對(dui)其它設(she)備(bei)水(shui)流量(liang)(liang)不造成(cheng)干擾,平(ping)(ping)(ping)衡(heng)(heng)(heng)閥可(ke)(ke)(ke)平(ping)(ping)(ping)衡(heng)(heng)(heng)水(shui)力(li)。電(dian)(dian)動(dong)(dong)(dong)(dong)的兩(liang)通(tong)閥、三通(tong)閥節流,可(ke)(ke)(ke)對(dui)環(huan)境(jing)負荷(he)(he)(he)數(shu)量(liang)(liang)進行調(diao)(diao)(diao)(diao)整。目前,動(dong)(dong)(dong)(dong)態平(ping)(ping)(ping)衡(heng)(heng)(heng)閥均帶(dai)有電(dian)(dian)動(dong)(dong)(dong)(dong)自(zi)(zi)控(kong)功能(neng)(neng),根據負荷(he)(he)(he)要求,對(dui)空(kong)調(diao)(diao)(diao)(diao)系統進行動(dong)(dong)(dong)(dong)態平(ping)(ping)(ping)衡(heng)(heng)(heng),以實(shi)現節能(neng)(neng)。所以,選(xuan)擇電(dian)(dian)動(dong)(dong)(dong)(dong)自(zi)(zi)控(kong)功能(neng)(neng)的動(dong)(dong)(dong)(dong)態平(ping)(ping)(ping)衡(heng)(heng)(heng)閥,即(ji)可(ke)(ke)(ke)平(ping)(ping)(ping)衡(heng)(heng)(heng)負荷(he)(he)(he)調(diao)(diao)(diao)(diao)整和水(shui)力(li)平(ping)(ping)(ping)衡(heng)(heng)(heng),可(ke)(ke)(ke)用(yong)電(dian)(dian)腦直接設(she)定流量(liang)(liang),還可(ke)(ke)(ke)簡化(hua)安裝,在(zai)狹小空(kong)間(jian)內也可(ke)(ke)(ke)安裝。
其次(ci),不宜多極設置。設置空調時,通常多極設計手動調節(jie)閥(fa),但按照該方法對(dui)動態平衡(heng)閥(fa)進行設置是錯(cuo)誤(wu)的。若下級(ji)的多個、一個設備將電動閥(fa)關閉(bi),上級(ji)平衡(heng)閥(fa)流(liu)(liu)量(liang)仍然保持(chi)不變(bian),可(ke)能(neng)會增(zeng)加(jia)下級(ji)未關設備的流(liu)(liu)量(liang),不僅增(zeng)加(jia)了水流(liu)(liu)造成,對(dui)使(shi)用(yong)功能(neng)也造成影響,增(zeng)加(jia)了經濟(ji)投資。
第(di)三(san),在空調設(she)計時,應按照冬(dong)夏(xia)供回水(shui)溫(wen)差(cha),對動態平衡閥進行(xing)合理設(she)置(zhi)。空調系統的(de)四管制,采用兩個平衡閥,即(ji)可滿足冬(dong)夏(xia)兩季的(de)不(bu)(bu)同水(shui)量(liang)要求,若冬(dong)夏(xia)兩季的(de)冷(leng)水(shui)溫(wen)差(cha)與供熱溫(wen)差(cha)不(bu)(bu)一致,水(shui)流(liu)量(liang)的(de)差(cha)異也較大(da),所以兩管制水(shui)系統必(bi)須按照冬(dong)夏(xia)兩季的(de)不(bu)(bu)同流(liu)量(liang)要求,對平衡閥進行(xing)設(she)置(zhi)。主(zhu)要有三(san)種方法:
(1)對(dui)可(ke)變流(liu)(liu)量的動態平(ping)衡(heng)(heng)閥(fa)(fa)進(jin)行設(she)置,在(zai)冬夏(xia)換(huan)(huan)季(ji)(ji)時,將(jiang)閥(fa)(fa)門(men)轉換(huan)(huan)即可(ke)。(2)對(dui)兩(liang)(liang)(liang)個(ge)(ge)平(ping)衡(heng)(heng)閥(fa)(fa)進(jin)行設(she)置,閥(fa)(fa)1根(gen)據(ju)冬季(ji)(ji)流(liu)(liu)量確定閥(fa)(fa)門(men),閥(fa)(fa)2根(gen)據(ju)冬夏(xia)兩(liang)(liang)(liang)季(ji)(ji)的zui大水(shui)量差(cha)確定閥(fa)(fa)門(men),冬季(ji)(ji)只開閥(fa)(fa)1,夏(xia)季(ji)(ji)開閥(fa)(fa)1、閥(fa)(fa)2,以(yi)兩(liang)(liang)(liang)個(ge)(ge)閥(fa)(fa)門(men)實現四(si)管制功能。(3)選(xuan)擇自控功能的動態平(ping)衡(heng)(heng)閥(fa)(fa),通過電腦設(she)定流(liu)(liu)量。
五結語
動態(tai)流(liu)量(liang)(liang)平(ping)衡閥(fa)分為固定式(shi)動態(tai)流(liu)量(liang)(liang)平(ping)衡閥(fa)和(he)(he)可(ke)調(diao)式(shi)動態(tai)流(liu)量(liang)(liang)平(ping)衡閥(fa),它們(men)都是在工作壓差(cha)范圍內維持(chi)自身流(liu)量(liang)(liang)不變,區別(bie)是前(qian)者出廠后流(liu)量(liang)(liang)不可(ke)調(diao),后者流(liu)量(liang)(liang)可(ke)調(diao)。對于設計流(liu)量(liang)(liang)已知的系統,選擇前(qian)者即可(ke),在使用中不需任何調(diao)試和(he)(he)維護,因(yin)此在暖通(tong)工程中使用動態(tai)平(ping)衡閥(fa)極為方便。
聯系我們